摘要(Abstract):
<正>心房颤动(atrial fibrillation,AF)是临床最常见的心律失常之一,发病率近2%[1]。流行病学资料显示,美国目前AF患者达266万,预计至2050年增加5倍,我国一般人群的发病率为0.77%[2]。AF主要危害之一是动脉系统血栓栓塞,其导致卒中的危险随年龄增长显著升高,在50~59岁人群中仅为1.5%,而80~89岁人群可高达23.5%[3]。临床研
关键词(KeyWords): 心房颤动;左心耳;介入治疗;进展
基金项目(Foundation):
作者(Author): 吴晓霞,马东星
参考文献(References):
- [1]Romero J,Perez IE,Krumerman A,et al.Left atrial appendage closure devices.Clin Med Insights Cardiol,2014,8:45-52.
- [2]陈忠秀,白文娟,饶莉.经皮左心耳封堵术预防心房颤动患者血栓栓塞的研究进展.中国介入心脏病学杂志,2013,21:248-250.
- [3]Wolf PA,Abbott RD,Kannel WB.Atrial fibrillation as an independent risk factor for stroke:the Framingham Study.Stroke,1991,22:983-988.
- [4]Blackshear JL,Odell JA.Appendage obliteration to reduce stroke in cardiac surgical patients with atrial fibrillation.Ann Thorac Surg,1996,61:755-759.
- [5]Thambidorai SK,Murray RD,Parakh K,et al.Utility of trans esophageal echocardiography in identification of thrombogenic milieu in patients with atrial fibrillation(an ACUTE ancillary study).Am J Cardiol,2005,96:935-941.
- [6]Di Biase L,Santangeli P,Anselmino M,et al.Does the left atrial appendage morphology correlate with the risk of stroke in patients with atrial fibrillation?Results from a multicenter study.J Am Coll Cardiol,2012,60:531-538.
- [7]Veinot JP,Harrity PJ,Gentile F,et al.Anatomy of the normal left atrial appendage:a quantitative study of age-related changes in 500 autopsy hearts:implications for echocardiographic examination.Circulation,1997,96:3112-3115.
- [8]Palios J,Paraskevaidis I.Thromboembolism prevention via transcatheter left atrial appendage closure with transeosophageal echocardiography guidance.Thrombosis,2014,2014:832752.
- [9]Kanderian AS,Gillinov AM,Pettersson GB,et al.Success of surgical left atrial appendage closure-assessment by transoesophageal echocardiography.J Am Coll Cardiol,2008,52:924-929.
- [10]Healey JS,Crystal E,Lamy A,et al.Left Atrial Appendage Occlusion Study(LAAOS):Results of a randomized controlled pilot study of left atrial appendage occlusion during coronary bypass surgery in patients at risk for stroke.Am Heart J,2005,150:288-293.
- [11]Fuller CJ,Reisman M.Stroke Prevention in Atrial Fibrillation:Atrial Appendage Closure.Curr Cardiol Rep,2011,13:159-166.
- [12]Dawson AG,Asopa S,Dunning J.Should patients undergoing cardiac surgery with atrial fibrillation have left atrial appendage exclusion?Interact Cardiovasc Thoracic Surg,2010,10:306-311.
- [13]Katz ES,TsiamtsiourisT,ApplebaumRM,et al.Surgical left atrial appendage ligation is frequently incomplete:A transesophageal echocardiographicstudy.J Am Coll Cardiol,2000,36:468-471.
- [14]Aryana A,Cavaco D,Arthur A,et al.Percutaneous endocardial occlusion of incompletely surgically ligated left atrial appendage.J Cardiovasc Electrophysiol,2013,24:968-974.
- [15]Camm AJ,Lip GY,De Caterina R,et al.2012 focused update of the ESC guidelines for the management of atrial fibrillation:an update of the 2010 ESC guidelines for the management of atrial fibrillation.Eur Heart J,2012,33:2719-2747.
- [16]Ostermayer SH,Reisman M,Kramer PH,et al.Percutaneous left atrial appendage transcatheter occlusion(PLAATO system)to prevent stroke in high-risk patients with non-rheumatic atrial fibrillation:results from the international multi-center feasibility trials.J Am Coll Cardiol,2005,46:9-14.
- [17]Block PC,Burstein S,Casale PN,et al.Percutaneous left atrial appendage occlusion for patients in atrial fibrillation suboptimal for warfarin therapy:5-year results of the PLAATO(Percutaneous Left Atrial Appendage Trans catheter Occlusion)Study.JACC Cardiovasc Interv,2009,2:594-600.
- [18]Bayard YL,Omran H,Neuzil P,et al.PLAATO(Percutaneous Left Atrial Appendage Transcatheter Occlusion)for prevention of cardio embolic stroke in non-anticoagulation eligible atrial fibrillation patients:results from the European PLAATO study.EuroI ntervention,2010,6:220-226.
- [19]Schwartz RS,Holmes DR,Van Tassel RA,et al.Left atrial appendage obliteration:mechanisms of healing and intracardiac integration.J Am Coll Cardiol Intv,2010,3:870-877.
- [20]Sick PB,Schuler G,Hauptmann KE,et al.Initial worldwide experience with the WATCHMAN left atrial appendage system for stroke prevention in atrial fibrillation.J Am Coll Cardiol,2007,49:1490-1495.
- [21]Holmes DR,Reddy VY,Turi ZG,et al.Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation:a randomised noninferiority trial.Lancet,2009,374:534-542.
- [22]Reddy VY,Holmes D,Doshi SK,et al.Safety of percutaneous left atrial appendage closure:results from the Watchman Left Atrial Appendage System for Embolic Protection in Patients with AF(PROTECT AF)clinical trial and the Continued Access Registry.Circulation,2011,123:417-424.
- [23]Holmes DR Jr,Kar S,Price MJ,et al.Prospective randomized evaluation of the Watchman Left Atrial Appendage Closure device in patients with atrial fibrillation versus long-term warfarin therapy:the PREVAIL trial.J Am Coll Cardiol,2014,64:1-12.
- [24]Reddy VY,Mobius-Winkler S,Miller MA,et al.Left atrial appendage closure with the watchman device in patients with a contraindication for oral anticoagulation.The ASAP Study(ASA plavix feasibility study with watchman left atrial appendage closure technology).J Am Coll Cardiol,2013,61:2551-2556.
- [25]Park JW,Bethencourt A,Sievert H,et al.Left atrial appendage closure with Amplatzer cardiac plug in atrial fibrillation:initial European experience.Catheter Cardiovasc Interv,2011,77:700-706.
- [26]Meerkin D,Butnaru A,Dratva D,et al.Early safety of the Amplatzer Cardiac Plug for left atrial appendage occlusion.Int J Cardiol,2013,168:3920-3925.
- [27]Plicht B,Konorza TF,Kahlert P,et al.Risk factors for thrombus formation on the Amplatzer Cardiac Plug after left atrial appendage occlusion.JACC Cardiovasc Interv,2013,6:606-613.
- [28]Lam SC,Bertog S,Gafoor S,et al.Left atrial appendage closure using the amulet device:An initial experience with the second generation amplatzer cardiac plug.Catheter Cardiovasc Interv,2014.doi:10.1002/ccd.25644.[Epub ahead of print]
- [29]Bartus K,Han FT,Bednarek J,et al.Percutaneous left atrial appendage suture ligation using the LARIAT device in patients with atrial fibrillation:Initial clinical experience.J Am Coll Cardiol,2013,62:108-118.
- [30]Lee RJ,Bartus K,Bednarek J,et al.Long-term efficacy of a percutaneous approach for LAA ligation in patients with atrial fibrillation.Heart Rhythm,2011,8:379-380.
- [31]Mosley WJ,Smith MR,Price MJ.Percutaneous management of late leak after lariat transcatheter ligation of the left atrial appendage in patients with atrial fibrillation at high risk for stroke.Catheter Cardiovasc Interv,2014,83:664-669.
- [32]Toumanides S,Sideris E,Agricola T,et al.Transcatheter patch occlusion of the left atrial appendage using surgical adhesives in high-risk patients with atrial fibrillation.J Am Coll Cardiol,2011,58:2236-2240.