Slender经皮冠状动脉介入治疗和Slender指引导管
赵慧强,陈晖,李虹伟
摘要(Abstract):
<正>[1993年,Kiemeni j等1]报道了首例经桡动脉冠状动脉介入治疗(transradial intervention,TRI)。近年来,随着技术的不断积累进步以及器械的不断更新,TRI已被广泛应用于临床冠心病介入治疗,并以其损伤小、局部并发症少及不必强制卧床等优点而倍受患者和介入医师青睐。在许多心脏介入中心,包括中国、日本以及欧洲的一些中心,经桡动脉入径已经成为经皮冠状动脉介入治疗(percutaneous coronary intervention,PCI)的首选入径。
关键词(KeyWords): 经皮冠状动脉介入治疗;Slender指引导管;桡动脉闭塞
基金项目(Foundation):
作者(Author): 赵慧强,陈晖,李虹伟
参考文献(References):
- [1]Kiemeneij F,Laarman GJ.Percutaneous transradial artery approach for coronarystent implantation.Cathet Cardiovasc Diagn,1993,30(2):173-178.
- [2]Stella PR,Kiemeneij F,Laarman GJ,et al.Incidence and outcome of radial artery occlusion following transradial artery coronary angioplasty.Catheter Cardiovasc Diagnosis,1997,40(2):156-158.
- [3]Sanmartin M,Gomez M,Rumoroso JR,et al.Interruption of blood flow during compression and radial artery occlusion after transradial catheterization.Catheter Cardiovasc Interv,2007,70(2):185-189.
- [4]Nagai S,Abe S,Saito T,et al.Ultrasonic assessment of vascular complications in coronary angiography and angioplasty af ter transradial approach.Am J Cardiol,1999,83(2):180-186.
- [5]Pancholy SB,Patel TM.Effect of duration of hemostatic compression on radial artery occlusion af ter transradial access.Catheter Cardiovasc Interv,2012,79(1):78-81.
- [6]Yoo BS,Lee SH,Ko JY,et al.Procedural outcomes of repeated transradial coronary procedure.Catheter Cardiovasc Interv,2003,58(3):301-304.
- [7]Yonetsu T,Kakuta T,Lee T,et al.Assessment of acute injuries and chronic intimal thickening of the radial artery after transradial coronary intervention by optical coherence tomography.Eur Heart J,2010,31(13):1608-1615.
- [8]Takeshita S,Shiono T,Takagi A,et al.Percutaneous coronary intervention using a novel 4-French coronary accessor.Catheter Cardiovasc Interv,2008,72(2):222-227.
- [9]Takeshita S,Asano H,Hata T,et al.Comparison of frequency of radial artery occlusion after 4Fr versus 6Fr transradial coronary intervention(f rom the novel angioplast y using coronar y accessortrial).Am J Cardiol,2014,113(12):1986-1989.
- [10]Mamas M,Fath-Ordoubadi F,Fraser DG.Atraumatic complex transradial intervention using large bore Sheathless guide catheter.Catheter Cardiovasc Interv,2008,72(3):357-364.
- [11]Tada N,Takizawa K,Kahata M,et al.Sheathless guide catheter coronary intervention via radial artery:single-center experience with9658 procedures.J Invasive Cardiol,2015,27(5):237-241.
- [12]Harding SA,Shah N,Briggs N,et al.Complex transradial percutaneous coronary intervention using a Sheathless guide catheter.Heart Lung Circ,2013,22(3):188-192.
- [13]Sciahbasi A,Mancone M,Cortese B,et al.Transradial percutaneous coronary interventions using Sheathless guiding catheters:a multicenter registry.J Interv Cardiol,2011,24(5):407-412.
- [14]赵慧强,陈晖,李东宝,等.经桡动脉用7.5F无鞘指引导管完成冠状动脉复杂病变介入治疗的初步经验.中国介入心脏病学杂志,2014,22(10):621-625。
- [15]Mizuno S,Takeshita S,Taketani Y,et al.Percutaneous coronary intervention using a virtual 3-Fr guiding catheter.Catheter Cardiovasc Interv,2010,75(7):983-988.
- [16]Tonomura D,Shimada Y,Yano K,et al.Feasibility and safety of a virtual 3-Fr sheathless-guiding system for percutaneous coronary intervention.Catheter Cardiovasc Interv,2014,84(3):426-435.
- [17]Honda T,Fujimoto K,Miyao Y.Feasibility of virtual 3-Fr percutaneous coronary intervention using standard guiding catheters.Postepy Kardiol Interwencyjnej,2014,10(4):231-237.
- [18]Tanaka A,Saito S.Percutaneous coronary intervention with a virtual 2-Fr system.Catheter Cardiovasc Interv,2010,76(5):684-686.
- [19]Ijichi T,Ikari Y.Transradial coronary angiography with virtual1 French,sheathless 3 French catheter.Catheter Cardiovasc Interv,2013,82(5):E676-E677.
- [20]Mamas MA,Fath-Ordoubadi F,Fraser D.Successful use of the Heartrail III catheter as a stent delivery catheter following failure of conventional techniques.Catheter Cardiovasc Interv,2008,71(3):358-363.
- [21]Mamas MA,Eichh?fer J,Hendry C,et al.Use of the Heartrail II catheter as a distal stent delivery device;an extended case series.Euro Intervention,2009,5(2):265-271.
- [22]Takahashi S,Saito S,Tanaka S,et al.New method to increase a backup support of a 6 French guiding coronary catheter.Catheter Cardiovasc Interv,2004,63(4):452-456.
- [23]Hynes B,Dollard J,Murphy G,et al.Enhancing back-up support during diffi cult coronary stent delivery:single-center case series of experience with the Heartrail II catheter.J Invasive Cardiol,2011,23(3):E43-E46.
- [24]Hiwatashi A,Iwabuchi M,Yokoi H,et al.PCI using a 4-Fr"child"guide catheter in a"mother"guidecatheter:Kyushu KIWAMI(R)ST registry.Catheter Cardiovasc Interv,2010,76(7):919-923.
- [25]Takeshita S,Shishido K,Sugitatsu K,et al.In vitro and human studies of a 4F double-coaxial technique("mother-child"confi guration)to facilitate stent implantation in resistant coronary vessels.Circ Cardiovasc Interv,2011,4(2):155-161.
- [26]赵慧强,陈晖,李虹伟,等.经桡动脉使用4 in 6子母导管技术治疗冠状动脉复杂病变的初步经验.中国介入心脏病学杂志,2016,24(12):688-691.
- [27]Tobita K,Takeshita S,Saito S.The 4-in-5 mother-child technique:5 Fr transradial coronary intervention for complex lesions using a 4Fr child catheter.J Invasive Cardiol,2013,25(8):406-408.
- [28]Honda T,Fujimoto K,Miyao Y.Successful percutaneous coronary intervention using a 4-in-3"Slender Mother and Child"PCI technique.Postepy Kardiol Interwencyjnej,2013,9(3):286-290.
- [29]Kumar S,Gorog DA,Secco GG,et al.The Guide Liner“child”catheter f or percutaneous coronary intervention-early clinical experience.J Invasive Cardiol,2010,22(10):495-498.
- [30]Repanas TI,Christopoulos G,Brilakis ES.“Candy Cane”guide catheter extension for stent delivery.J Invasive Cardiol,2015,27(8):E169-E170.
- [31]Waterbury TM,Sorajja P,Bell MR,et al.Experience and complications associated with use of guide extension catheters in percutaneous coronary intervention.Catheter Cardiovasc Interv,2016,88(7):1057-1065.
- [32]Mozid AM,Davies JR,Spratt JC.The utility of a guideliner?catheter in retrograde percutaneous coronary intervention of a chronic total occlusion with reverse cart-the“capture”technique.Catheter Cardiovasc Interv,2014,83(6):929-932.
- [33]Kiemeneij F,Fraser D,Slagboom T,et al.Hydrophilic coating aids radial sheath withdrawal and reduces patient discomfort following transradial coronary intervention:a randomized double-blind comparison of coated and uncoated sheaths.Catheter Cardiovasc Interv,2003,59(2):161-164.
- [34]Yoshimachi F,Kiemeneij F,Masutani M,et al.Safety and feasibility of the new 5Fr Glidesheath Slender.Cardiovasc Interv Ther,2016,31(1):38-41.
- [35]Aminian A,Dolatabadi D,Lefebvre P,et al.Initial experience with the Glidesheath Slender for transradial coronary angiography and intervention:a feasibility study with prospective radial ultrasound follow-up.Catheter Cardiovasc Interv,2014,84(3):436-442.
- [36]Matsukage T,Yoshimachi F,Masutani M,et al.A new 0.010-inch guidewire and compatible balloon catheter system:the IKATEN registry.Catheter Cardiovasc Interv,2009,73(5):605-610.
- [37]Matsukage T,Masutani M,Yoshimachi F,et al.A prospective multicenter registry of 0.010-inch guidewire and compatible system f or chronic total occlusion:the PIKACHU registry.Catheter Cardiovasc Interv,2010,75(7):1006-1012.