射频球囊成形术的研究现状
周玉杰,黄永麟,汪丽慧
摘要(Abstract):
<正>经皮腔内冠状动脉成形术(PTCA)自1977年首次应用于临床至今,其技术和器械虽几经改进,但扩张动脉段再狭窄(RS)的发生率一直维持在30%~50%.某些病例甚至更高,应用药物及机械旋切、激光消融及血管内支架等措施对RS的预防和治疗尚未取得满意的疗效,因此,寻求新的成形技术来降低RS发生率成为当前研究的热点之一.
关键词(KeyWords):
基金项目(Foundation):
作者(Author): 周玉杰,黄永麟,汪丽慧
参考文献(References):
- [1]Mcbride W.Lange RA,Hillis LD.Restenosis after successful coronary angioplasty:Pathopysiology and prevention,N Engl J Med,1988,57:220.
- [2]Nobuyoshi M.Kimura H,et al.Restenosis After Successful Percutaneous Transluminal Coronaty Angioplasty:Serial Angiographic Follow-up of 229 patients,J Am Coll Cardiol,1988,12:616.
- [3]Walter RM,Hermans MD,David P,et al.Morphologic changes during follow-up after successful percutanous transluminal coronary balloon angioplasty:Quantitative angiographic analysis in 778 lesions-further evidence for the restenosis paradox.Am Heart J,1994,127:483.
- [4]Kuntz RE.Donal DS,Baim DS,et al.Defining Coronary Restenosis Newer Clinlcal and Angiographic Paradigms.Circalation,1993,88:1310.
- [5]Popma JJ,Califf RM,Topol EJ,et al.Chinical Trials of Restenosis After Coronary Angioplasty.Circalation,1991,84:1426.
- [6]Kuntz RE,Hinohara MT,Safian RD,et al.Restenosis After Directional Coronary Atherectomy;Effects of Luminal Diameter and Deep Wall Excision.Circalation,1992,86:1394.
- [7]Gesch HJ,Rande JD,Zelinsky R,et al.Percutaneous coronary mid-infrared laser angioplasty.Am Hear,J,1991.122:552.
- [8]Ellis SG.Savage M,Fischman D.et al.Restenosis After Placement of Palmaz-Schatz Stents in Native Coronary Arteries:Initial Results of a Multicenter Experience.Circulation,1992.86:1836
- [9]Sigel B,Acevedo FJ,Electroconductive union of blood vesseles;a preliminary experimental study.J Surg Ress.1963,3:90.
- [10]Sigel B,Dunn MR.The mechanism of blood vessel closure by high frequency electrocoagulation.Surg Gynecol Obstel,1965,121:825.
- [11]Lepage JR,Lewis JE,Ruiz OF,et al.Angiopyroplasty using electromagnetically focused heat.Angiology,1987,38:520.
- [12]Lee MA.Morady F,Kadish AH.Catheter modification of the AV node with radiofrequency energy for care of AV nodal reetrant tachy cardia results in patients.PACE,1990,13:498.
- [13]Huag SK,Graham AR,Hoyt RH.et al.Transcatheter desiccation of the canine left ventride using radiofrequency energy:a pilotsudy.AM Heart J,1987.114:42.
- [14]Hung SK,Bharati,Graham AR,et al.Closet chest catheter desiccation of the atrioventriculer:action using radiofreqency energy-a new method of catherter ablation.J Am Coll Cardiol,1987,9:349.
- [15]Litvack F,Grundfest W,Friedrich M,et al.“Hot-tip”an gioplasty by novel radiofrequency cather(abstr).Circulation,1987,76(Suppl Ⅳ):Ⅳ—47.
- [16]Lee BI,Beckter GJ,Waller BF,et al.Thermal compression and molding of atherosclerotic vascular tissue with use of radiofrequency energy:implications for radiofrequency balloon angioplasty.J Am Coll Cardiol,1989,13:1167.
- [17]Barry KJ,Kaplan J,Connolly RJ,et al.The errect of radiofrequency generated thermal energy on the mechanical and higtologic characteristics of the arterial wall in vivo :implications for radiofrequency angioplasty.Am Hear J,1989,117:332.
- [18]Fram DB,Gillam LD,Aretz TA,et al.Low pressure radiofrequency balloon angioplasty:Evaluation in porcine peripheral arteries.J AM Coll Cardiol,1993,21:1512.
- [19]Haines DE,Watson DD:Tissue heating during radiofrequency catheter ablation:A thermodynamic model and observation in isolated perfused and superfused canine right ventricular free wall.PACE,1989,12:962.
- [20]Wittkampf FHM,Hauer RNW,Robles de Medina EO.Control of radiofrequency lesson size by power regulation.Circulation,1989,80:962—968.
- [21]Langberg JJ,Lee MA,Chin MC,Rosenqvist M.Radiofrequency catheter ablation:The effect of electrode size on lesion volume in vivo.PACE,1990,13:1242.
- [22]Blouin LT,Marcus FI.The effect of electrode desize on efficien of delivery of radiofreqency energy to cardiac tissue in vitro.PACE,1989,12:136.
- [23]Haines DE,Verow AF.The impedance rise during radiofreqency ablation in vivo is prevented by maintaining an electrode tip temperature below the boiling point(abstract).Circulation,1988,80(Suppl Ⅱ):Ⅱ-41.
- [24]Becker GJ,Lee BI,Waller BF,et al.Potential of radiofreqency Balloon Angioplasty:Weld Strengths,Dose-Response Relation ship,and Corre lative Histology Radiology,1990,174:1003.
- [25]Levine AB,Spears JR.Laser angioplasty,Cardiac Catheterization,Angiography and Interv