CT心肌灌注成像研究进展
李又洁
摘要(Abstract):
<正>冠心病是发达国家人口致死的主要原因之一,美国每年新增100多万例患者~([1])。冠状动脉CT血管造影(computed tomographic angiography,CTA)已经成为一种检查低、中危冠心病危险因素人群中冠状动脉狭窄无创且有效的方法~([2])。但是,对于可能患有高危冠心病或粥样硬化斑块较重的患者,CTA易高估病变部位的狭窄程度~([3]),可能会增加有创性造影检查概率。单光子发射计算机断层扫描心肌灌注成像
关键词(KeyWords): 体层摄影术;冠心病;心肌灌注成像;心肌缺血
基金项目(Foundation):
作者(Author): 李又洁
参考文献(References):
- [1]Roger VL,Go AS,Lloyd-Jones DM,et al.Heart disease and stroke statistics--2011 update:a report from the American Heart Association.Circulation,2011,123(4):e18-e209.
- [2]Williams MC,Hunter A,Shah AS,et al.Use of coronary computed tomographic angiography to guide management of patients with coronary disease.J Am Coll Cardiol,2016,67(15):1759-1768.
- [3]Taylor AJ,Cerqueira M,Hodgson JM,et al.ACCF/SCCT/ACR/AHA/ASE/ASNC/SCAI/SCMR 2010 appropriate use criteria for cardiac computed tomography.Circulation,2010,4(6):407.e1-407.e33.
- [4]Tonino PA,Fearon WF,De Bruyne B,et al.Angiographic versus functional severity of coronary artery stenoses in the FAME study fractional flow reserve versus angiography in multivessel evaluation.J Am Coll Cardiol,2010,55(25):2816-2821.
- [5]Rocha-Filho JA,Blankstein R,Shturman LD,et al.Incremental value of adenosine-induced stress myocardial perfusion imaging with dual-source CT at cardiac CT angiography.Radiology,2010,254(2):410-419.
- [6]Arbab-Zadeh A,Miller JM,Rochitte CE,et al.Diagnostic accuracy of computed tomography coronary angiography according to pre-test probability of coronary artery disease and severity of coronary arterial calcification.The CORE-64(coronary artery evaluation using 64-row multidetector computed tomography angiography)international multicenter study.J Am Coll Cardiol,2012,59(4):379-387.
- [7]Caruso D,Eid M,Schoepf UJ,et al.Dynamic CT myocardial perfusion imaging.Eur J Radiol,2016,85(10):1893-1899.
- [8]Rossi A,Merkus D,Klotz E,et al.Stress myocardial perfusion:imaging with multidetector CT.Radiology,2014,270(1):25-46.
- [9]CannaòPM,Schoepf UJ,Muscogiuri G,et al.Technical prerequisites and imaging protocols for dynamic and dual energy myocardial perfusion imaging.Eur J Radiol,2015,84(12):2401-2410.
- [10]Nikolaou K,Knez A,Sagmeister S,et al.Assessment of myocardial infarctions using multidetector-row computed tomography.J Comput Assist Tomogr,2004,28(2):286-292.
- [11]Krombach GA,Niendorf T,Günther RW,et al.Characterization of myocardial viability using MR and CT imaging.Eur Radiol,2007,17(6):1433-1444.
- [12]Habis M,Capderou A,Ghostine S,et al.Acute myocardial infarction early viability assessment by 64-slice computed tomography immediately after coronary angiography:comparison with low-dose dobutamine echocardiography.J Am Coll Cardiol,2007,49(11):1178-1185.
- [13]Patel AR,Lodato JA,Chandra S,et al.Detection of myocardial perfusion abnormalities using ultra-low radiation dose regadenoson stress multidetector computed tomography.J Cardiovasc Comput Tomogr,2011,5(4):247-254.
- [14]Meinel FG,De Cecco CN,Schoepf UJ,et al.First-arterial-pass dual-energy CT for assessment of myocardial blood supply:do we need rest,stress,and delayed acquisition?Comparison with SPECT.Radiology,2014,270(3):708-716.
- [15]Blankstein R,Shturman LD,Rogers IS,et al.Adenosineinduced stress myocardial perfusion imaging using dual-source cardiac computed tomography.J Am Coll Cardiol,2009,54(12):1072-1084.
- [16]Feuchtner G,Goetti R,Plass A,et al.Adenosine stress highpitch 128-slice dual-source myocardial computed tomography perfusion for imaging of reversible myocardial ischemia:comparison with magnetic resonance imaging.Circ Cardiovasc Imaging,2011,4(5):540-549.
- [17]Bamberg F,Becker A,Schwarz F,et al.Detection of hemodynamically significant coronary artery stenosis:incremental diagnostic value of dynamic CT-based myocardial perfusion imaging.Radiology,2011,260(3):689-698.
- [18]Ebersberger U,Marcus RP,Schoepf UJ,et al.Dynamic CT myocardial perfusion imaging:performance of 3D semi-automated evaluation software.Eur Radiol,2014,24(1):191-199.
- [19]Huber AM,Leber V,Gramer BM,et al.Myocardium:dynamic versus single-shot CT perfusion imaging.Radiology,2013,269(2):378-386.
- [20]Baxa J,Hromádka M,edivy J,et al.Regadenoson-stress dynamic myocardial perfusion improves diagnostic performance of CT angiography in assessment of intermediate coronary artery stenosis in asymptomatic patients.Biomed Res Int,2015,2015:105629.
- [21]Greif M,von Ziegler F,Bamberg F,et al.CT stress perfusion imaging for detection of haemodynamically relevant coronary stenosis as defined by FFR.Heart,2013,99(14):1004-1011.
- [22]Bastarrika G,Ramos-Duran L,Rosenblum MA,et al.Adenosine-stress dynamic myocardial CT perfusion imaging:initial clinical experience.Invest Radiol,2010,45(6):306-313.
- [23]Meinel FG,Ebersberger U,Schoepf UJ,et al.Global quantification of left ventricular myocardial perfusion at dynamic CT:feasibility in a multicenter patient population.AJR Am J Roentgenol,2014,203(2):W174-W180.
- [24]George RT,Mehra VC,Chen MY,et al.Myocardial CT perfusion imaging and SPECT for the diagnosis of coronary artery disease:a head-to-head comparison from the CORE320multicenter diagnostic performance study.Radiology,2015,274(2):626.
- [25]Takx RA,Blomberg BA,El Aidi H,et al.Diagnostic accuracy of stress myocardial perfusion imaging compared to invasive coronary angiography with fractional flow reserve meta-analysis.Circ Cardiovasc Imaging,2015,8(1).pii:e002666.