摘要(Abstract):
目的探讨经桡动脉入径采用球囊辅助技术(BAT)协助的无鞘技术引导7 F指引导管行经皮冠状动脉介入治疗(PCI)的可行性。方法前瞻性分析2019年1月至8月首都医科大学附属北京友谊医院心内科使用BAT协助的无鞘技术引导7 F指引导管行PCI患者的临床资料、影像资料、术后恢复情况,对该技术的可行性和安全性进行评价。结果 12例患者采用BAT协助的无鞘技术引导7 F指引导管全部成功,无患者出现血管径路相关的并发症。所有患者PCI成功率为100%。结论经桡动脉入径采用BAT协助的无鞘技术引导7 F指引导管行PCI有很好的可行性和安全性,可作为部分复杂病变患者经桡动脉行PCI的首选方法。
关键词(KeyWords): 冠状动脉疾病;经皮冠状动脉介入治疗;无鞘技术;球囊辅助技术;指引导管
基金项目(Foundation):
作者(Author): 赵慧强,金洪珍,王东兴,周力,丁晓松,高翔宇,梁思文,刘洪阳,陈晖,黄榕翀,李虹伟
参考文献(References):
- [1]Neumann FJ,Sousa-Uva M,Ahlsson A,et al.ESC Scientific Document Group,2018 ESC/EACTS Guidelines on myocardial revascularization.Eur Heart J,2019,40(2):87-165.
- [2]Levine GN,Bates ER,Blankenship JC,et al.2011 ACCF/AHA/SCAI guideline for percutaneous coronary intervention.A report of the American College of Cardiology Foundation/American Heart Association task force on practice guidelines and the Society for Cardiovascular Angiography and Interventions.J Am Coll Cardiol,2011,58(24):e44-e122.
- [3]Mamas MA,George S,Ratib K,et al.5-Fr sheathless transradial cardiac catheterization using conventional catheters and balloon assisted tracking,a new approach to downsizing.Cardiovasc Revasc Med,2017,18(1):28-32.
- [4]贾三庆,郭春艳,滕一星,等.成人右侧桡动脉舒张期最大内径分布调查.中国介入心脏病学杂志,2004,12(3):162.
- [5]Saito S,Ikei H,Hosokawa G,et al.Influence of the ratio between radial artery inner diameter and sheath outer diameter on radial artery fl ow after transradial coronary intervention.Catheter Cardiovasc Interv,1999,46(2):173-178.
- [6]Mamas M,Fath-Ordoubadi F,Fraser DG.Atraumatic complex transradial intervention using large bore Sheathless guide catheter.Catheter Cardiovasc Interv,2008,72(3):357-364.
- [7]Sciahbasi A,Mancone M,Cortese B,et al.Transradial percutaneous coronary interventions using Sheathless guiding catheters:a multicenter registry.J Interv Cardiol,2011,24(5):407-412.
- [8]Lozano I,Rondan J,Avanzas P,et al.Rotational atherectomy through radial access with a 7.5 Fr Sheathless guiding catheter.Rev Esp Cardiol,2011,64(3):247-248.
- [9]Harding SA,Shah N,Briggs N,et al.Complex transradial percutaneous coronary intervention using a Sheathless guide catheter.Heart Lung Circ,2013,22(3):188-192.
- [10]赵慧强,陈晖,李东宝,等.经桡动脉用7.5 F无鞘指引导管完成冠状动脉复杂病变介入治疗的初步经验.中国介入心脏病学杂志,2014,22(10):621-625.
- [11]From AM,Gulati R,Prasad A,et al.Sheathless transradial intervention using standard guide catheters.Catheter Cardiovasc Interv,2010,76(7):911-916.
- [12]Chen HC,Lee WC,Hsueh SK,et al.Transradial percutaneous coronary intervention for chronic total occlusion of coronary artery disease using sheathless standard guiding catheters.Int JCardiol Heart Vasc,2014,6:35-41.
- [13]Dautov R,Ribeiro HB,Abdul-Jawad Altisent O,et al.Effectiveness and saf ety of the transradial 8Fr Sheathless approach f or revascularization of chronic total occlusions.Am J Cardiol,2016,118(6):785-789.
- [14]李其勇,贺勇,刘忠贵,等.经桡动脉无鞘技术在冠状动脉左主干病变介入治疗中的应用.中国介入心脏病学杂志,2012,20(5):245-247.
- [15]Patel T,Shah S,Pancholy S.Balloon-assisted tracking of a guide catheter through difficult radial anatomy:a technical report.Catheter Cardiovasc Interv,2013,81(5):E215-E218.
- [16]Patel T,Shah S,Pancholy S,et al.Balloon-assisted tracking:a must-know technique to overcome difficult anatomy during transradial approach.Catheter Cardiovasc Interv,2014,83(2):211-220.
- [17]Felekos I,Hussain R,Patel SJ,et al.Balloon-assisted tracking:A practical solution to avoid radial access failure due to difficult anatomical challenges.Cardiovasc Revasc Med,2018,19(5 Pt B):564-569.
- [18]Obaid D,Hailan A,Chase A,et al.Balloon-assisted tracking use reduces radial artery access failure in an experienced radial center and is feasible during primary PCI for STEMI.J Invasive Cardiol,2017,29(7):219-224.
- [19]Wojciuk J,Beijk MA,Goode G,et al.Balloon-assisted tracking technique as‘a way forward’for transradial intervention.Coron Artery Dis,2019,30(6):440-447.
- [20]Deora S,Shah S,Patel T.Balloon-assisted tracking in dealing with radial artery loop by transradial approach:a technical report.JInvasive Cardiol,2014,26(5):E61-E62.
- [21]D’Amario D,Paraggio L,Porto I.Combining balloon-assisted tracking and sheathless guiding catheter:unloosening the Gordian knot.Cardiovasc Revasc Med,2015,16(7):432-434.
- [22]汪国忠,赵全明,陈清,等.球囊辅助通过技术在桡动脉通过失败时的应用分析.中国介入心脏病学杂志,2019,27(5):288-291.
- [23]Dharma S,Gilchrist IC,Patel T.Balloon-assisted tracking:a solution to severe subclavian tortuosity encountered during transradial primary PCI.Int J Angiol,2016,25(2):134-136.