摘要(Abstract):
经导管三尖瓣置换术(TTVR)创伤小,恢复快,围术期死亡率远低于外科手术,是三尖瓣外科置换术后生物瓣膜衰败患者的首选治疗方式。但是当输送系统体积较大时,由于外科换瓣后瓣口面积减小,瓣架限制操作,可能会出现输送系统推进困难,并且由于右心路径曲折,导丝提供的支撑力有限,操作难度也会有所增加。本病例报道中的患者即为外科三尖瓣置换后生物瓣衰败,在进行TTVR时出现输送系统跨瓣困难,笔者团队及时运用本中心提出的支撑鞘与圈套导丝平行锚定(PASS)技术,使用大尺寸支撑鞘联合圈套器套住主路加硬导丝头端,将曲折路径拉直,为加硬导丝提供额外支撑力,最终成功推进输送系统跨过三尖瓣,为破解TTVR术中跨瓣困难提供了切实有效的借鉴。
关键词(KeyWords): 经导管三尖瓣置换术;输送系统;圈套器;支撑鞘;推进技术
基金项目(Foundation):
作者(Author): 方雁行,潘文志,周达新,葛均波
参考文献(References):
- [1] Scotti A,Sturla M,Granda JF,et al. Outcomes of isolated tricuspid valve replacement:a systematic review and meta-analysis of 5,316 patients from 35 studies[J]. EuroIntervention,2022,18(10):840-851. DOI:10.4244/EIJ-D-22-00442.
- [2] Otto CM,Nishimura RA,Bonow RO,et al. 2020 ACC/AHA Guideline for the management of patients with valvular heart disease:executive summary:a report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines[J]. Circulation,2021,143(5):e35-e71. DOI:10.1161/CIR.0000000000000932.
- [3] Pan W,Hou S,Chen S,et al. Advancing a bulky delivery system using a novel technique during percutaneous pulmonary valve implantation[J]. Tex Heart Inst J,2022,49(5):e207541. DOI:10.14503/THIJ-20-7541.
- [4] Maschietto N,Sperotto F,Esch JE,et al. The snared wire technique for Sapien valve implantation in the pulmonary position[J]. Catheter Cardiovasc Interv,2020,96(4):898-903.DOI:10.1002/ccd.28970.
- [5] Haas NA,Vcasna R,Laser KT,et al. The standing of percutaneous pulmonary valve implantation compared to surgery in a non-preselected cohort with dysfunctional right ventricular outflow tract-Reasons for failure and contraindications[J]. J Cardiol,2019,74(3):217-222. DOI:10.1016/j.jjcc.2019.03.021.
- [6] Esmaeili A,Bollmann S,Khalil M,et al. Percutaneous pulmonary valve implantation for reconstruction of a patchrepaired right ventricular outflow tract[J]. J Interv Cardiol,2018,31(1):106-111. DOI:10.1111/joic.12443.
- [7] Khambadkone S,Coats L,Taylor A,et al. Percutaneous pulmonary valve implantation in humans:results in 59consecutive patients[J]. Circulation,2005,112(8):1189-1197. DOI:10.1161/CIRCULATIONAHA.104.523266.
- [8] Sinha S,Aboulhosn J,Asnes J,et al. Initial results from the of flabel use of the SAPIEN S3 valve for percutaneous transcatheter pulmonary valve replacement:a multi-institutional experience[J]. Catheter Cardiovasc Interv,2019,93(3):455-463.DOI:10.1002/ccd.27973.
- [9] Yao YJ,Zhao ZG,Wang X,et al. Snaring self-expanding devices to facilitate transcatheter aortic valve replacement in patients with complex aortic anatomies[J]. J Clin Med,2023,12(15):5067. DOI:10.3390/jcm12155067.