左心室心内膜起搏心脏再同步化治疗现状及进展
谢启应,孙泽琳,杨天伦
摘要(Abstract):
<正>研究证实,心脏再同步化治疗(cardiac resynchronization therapy,CRT)可改善多数患者左心室射血分数(left ventricular ejection fractions,LVEF),改善伴QRS波群增宽心力衰竭患者的心功能和预后~[1-2],对心电图呈典型完全性左束支传导阻滞、QRS波群宽度≥150 ms、肺动脉压较低和LVEF显著降低等特征的患者应答率更高,尤其是女性~[3-4]。目前,常规CRT是将左心室导线经冠状静脉窦(coronary
关键词(KeyWords): 心内膜起搏;心脏再同步化治疗;左心室;心力衰竭
基金项目(Foundation):
作者(Author): 谢启应,孙泽琳,杨天伦
参考文献(References):
- [1]Goldenberg I,Kutyifa V,Klein HU,et al.Survival with cardiacresynchronization therapy in mild heart failure.N Engl J Med,2014,370:1694-1701.
- [2]Stavrakis S,Lazzara R,Thadani U.The benefit of cardiac resynchronization therapy and QRS duration:a meta-analysis.J Cardiovasc Electrophysiol,2012,23:163-168.
- [3]Killu AM,Grupper A,Friedman PA,et al.Predictors and outcomes of"super-response"to cardiac resynchronization therapy.J Card Fail,2014,20:379-386.
- [4]邹彤,杨杰孚.心脏再同步化治疗新指南要点及进展.中国介入心脏病学杂志,2014,22:538-542.
- [5]Khan FZ,Virdee MS,Gopalan D,et al.Characterization of the suitability of coronary venous anatomy for targeting left ventricular lead placement in patients undergoing cardiac resynchronization therapy.Europace,2009,11:1491-1495.
- [6]周宏,李振,贺贵宝,等.左室心外膜电极起搏在冠状静脉窦左室电极植入失败时的应用.江苏实用心电学杂志,2012,21:162-164.
- [7]秦胜梅,宿燕岗,陈海燕,等.心脏再同步化治疗无反应者的治疗——升级为左室双部位起搏(附二例报道).中国心脏起搏与心电生理杂志,2015,29:18-23.
- [8]Zanon F,Baracca E,Pastore G,et al.Multipoint pacing by a left ventricular quadripolar lead improves the acute hemodynamic response to CRT compared with conventional biventricular pacing at any site.Heart Rhythm,2015,12:975-981.
- [9]谢启应,孙泽琳,杨天伦,等.经房间隔穿刺左心室内膜起搏心脏再同步化治疗并文献分析.中国现代医学杂志,2015,25:88-93.
- [10]Domenichini G,Diab I,Campbell NG,et al.A highly effective technique for transseptal endocardial left ventricular lead placement for delivery of cardiac resynchronization therapy.Heart Rhythm,2015,12:943-949.
- [11]Betts TR,Gamble JH,Khiani R,et al.Development of a technique for left ventricular endocardial pacing via puncture of the interventricular septum.Circ Arrhythm Electrophysiol,2014,7:17-22.
- [12]Gamble JH,Bashir Y,Rajappan K,et al.Left ventricular endocardial pacing via the interventricular septum for cardiac resynchronization therapy:first report.Heart Rhythm,2013,10:1812-1814.
- [13]Auricchio A,Delnoy PP,Regoli F,et al.First-in-man implantation of leadless ultrasound-based cardiac stimulation pacing system:novel endocardial left ventricular resynchronization therapy in heart failure patients.Europace,2013,15:1191-1197.
- [14]Kassai I,Friedrich O,Ratnatunga C,et al.Feasibility of percutaneous implantation of transapical endocardial left ventricular pacing electrode for cardiac resynchronization therapy.Europace,2011,13:1653-1657.
- [15]Kassai I,Foldesi C,Szekely A,et al.New method for cardiac resynchronization therapy:transapical endocardial lead implantation for left ventricular free wall pacing.Europace,2008,10:882-883.
- [16]宿燕岗,聂振宁,秦胜梅,等.经房间隔穿刺行左心室内膜植入心脏再同步治疗除颤器一例.中华心律失常学杂志,2012,16:384-386.
- [17]John Morgan.ALSYNC:LV Endocardial Pacing Could Help in CRT Nonresponse.[C/OL]2012-05-12.http://www.medscape.com/viewarticle/824972.
- [18]Niazi I,Dhala A,Choudhuri I,et al.Cardiac resynchronization therapy in patients with challenging anatomy due to venous anomalies or adult congenital heart disease.Pacing Clin Electrophysiol,2014,37:1181-1188.
- [19]Mondoly P,Marachet MA,Massabuau P,et al.Transseptal implantation of a left ventricular pacing lead for an ectopic location of the coronary sinus ostium in the left atrium.Pacing Clin Electrophysiol,2013,36:e51-e52.
- [20]Holda MK,Klimek-Piotrowska W,Koziej M,et al.Anatomical variations of the coronary sinus valve(Thebesian valve):implications for electrocardiological procedures.Europace,2015,17:921-927.
- [21]Biffi M,Exner DV,Crossley GH,et al.Occurrence of phrenic nerve stimulation in cardiac resynchronization therapy patients:the role of left ventricular lead type and placement site.Europace,2013,15:77-82.
- [22]Rickard J,Kumbhani DJ,Popovic Z,et al.Characterization of super-response to cardiac resynchronization therapy.Heart Rhythm,2010,7:885-889.
- [23]Merchant FM,Heist EK,Mc Carty D,et al.Impact of segmental left ventricle lead position on cardiac resynchronization therapy outcomes.Heart Rhythm,2010,7:639-644.
- [24]Chalil S,Stegemann B,Muhyaldeen SA,et al.Effect of posterolateral left ventricular scar on mortality and morbidity following cardiac resynchronization therapy.Pacing Clin Electrophysiol,2007,30:1201-1209.
- [25]Derumeaux G,Ovize M,Loufoua J,et al.Assessment of nonuniformity of transmural myocardial velocities by color-coded tissue Doppler imaging:characterization of normal,ischemic,and stunned myocardium.Circulation,2000,101:1390-1395.
- [26]Derval N,Steendijk P,Gula LJ,et al.Optimizing hemodynamics in heart failure patients by systematic screening of left ventricular pacing sites:the lateral left ventricular wall and the coronary sinus are rarely the best sites.J Am Coll Cardiol,2010,55:566-575.
- [27]Padeletti L,Pieragnoli P,Ricciardi G,et al.Acute hemodynamic effect of left ventricular endocardial pacing in cardiac resynchronization therapy:assessment by pressure-volume loops.Circ Arrhythm Electrophysiol,2012,5:460-467.
- [28]Sohal M,Shetty A,Niederer S,et al.Delayed trans-septal activation results in comparable hemodynamic effect of left ventricular and biventricular endocardial pacing:insights from electroanatomical mapping.Circ Arrhythm Electrophysiol,2014,7:251-258.
- [29]Tayeh O,Farouk W,Elazab A,et al.Potential pro-arrhythmic effect of cardiac resynchronization therapy.J Saudi Heart Assoc,2013,25:181-189.
- [30]Mykytsey A,Maheshwari P,Dhar G,et al.Ventricular tachycardia induced by biventricular pacing in patient with severe ischemic cardiomyopathy.J Cardiovasc Electrophysiol,2005,16:655-658.
- [31]Konings TC,Koolbergen DR,Bouma BJ,et al.Iatrogenic perforation of the posterior mitral valve leaflet:a rare complication of pacemaker lead placement.J Am Soc Echocardiogr,2008,21:512.e5-e7.
- [32]Rodriguez Y,Baltodano P,Tower A,et al.Management of symptomatic inadvertently placed endocardial leads in the left ventricle.Pacing Clin Electrophysiol,2011,34:1192-1200.
- [33]Irvine JN,La Par DJ,Mahapatra S,et al.Treatment of a malpositioned transcutaneous ventricular pacing lead in the left ventricle via direct aortic puncture.Europace,2011,13:1207-1208.
- [34]Reising S,Safford R,Castello R,et al.A stroke of bad luck:left ventricular pacemaker malposition.J Am Soc Echocardiogr,2007,20:1316.e1-e3.
- [35]Wedekind H,Muller JG.Visual diagnosis in cardiology:malposition of dual-chamber pacemaker lead.Anaesth Intensive Care,2007,35:806.
- [36]Lekkerkerker JC,van Nieuwkoop C,Trines SA,et al.Risk factors and time delay associated with cardiac device infections:Leiden device registry.Heart,2009,95:715-720.
- [37]Lau EW.Yoked catheter positioning in transseptal endocardial left ventricular lead placement.Pacing Clin Electrophysiol,2011,34:884-893.
- [38]Elencwajg B,López Cabanillas N,Cardinali EL,et al.The Jurdham procedure:endocardial left ventricular lead insertion via a femoral transseptal sheath for cardiac resynchronization therapy pectoral device implantation.Heart Rhythm,2012,9:1798-1804.
- [39]Calvo N,Arguedas H,Canepa JP,et al.Endocardial left ventricular lead placement from the left subclavian vein approach.Europace,2014,16:1857-1859.
- [40]Moria-Vázquez P,Barba-Pichardo R,Gamero JV,et al.Implantation via the femoral vein of a biventricular defibrillator with transseptal endocardial left ventricular pacing.Rev Esp Cardiol,2009,62:1503-1505.
- [41]Reinig M,White M,Levine M,et al.Left ventricular endocardial pacing:a transarterial approach.Pacing Clin Electrophysiol,2007,30:1464-1468.