远端保护装置在冠状动脉介入治疗中的应用进展
张大鹏,杨新春,王乐丰
摘要(Abstract):
关键词(KeyWords):
基金项目(Foundation):
作者(Author): 张大鹏,杨新春,王乐丰
参考文献(References):
- 1MichaelsAD,GibsonCM,BarronHW.Microvasculardysfunctioninacutemyocardialinfarction:focusontherolesofplateletand inflammatorymediatorsintheno reflowhenomenon.AmJCardiol,2000,85:50B60B.
- 2TopolEJ,YadavJS.Recognitionoftheimportanceofembolizationinatheroscleroticvasculardisease.Circulation,2000,101:570580.
- 3HenriquesJP,ZijlstraF,OttervangerJP,etal.Incidenceandclinicalsignificanceofdistalembolizationduringprimaryangioplastyforacutemyocardialinfarction.EurHeartJ,2002,23:11121117.
- 4GiriS,MitchelJF,HirstJA,etal.Synergybetweenintracoronarystentingandabciximabinimprovingangiographicandclinicaloutcomesofprimaryangioplastyinacutemyocardialinfarction.AmJCardiol,2000,86:269274.
- 5YadavJS,WholeyMH,KuntzRE,etal.Protectedcarotid arterystentingversusendarterectomyinhigh riskpatients.NEnglJMed,2004,351:14931501.
- 6WaksmanR,DouglasJSJr,ScottNA,etal.Distalembolizationiscommonafterdirectionalatherectomyincoronaryarteriesandsaphenousveingrafts.AmHeartJ,1995,129:430435.
- 7GrubeE,SchoferJ,WebbJ,etal.Evaluationofaballoonocclusion andaspirationsystemforprotectionfromdistalembolizationduringstentinginsaphenousveingrafts.AmJCardiol,2002,89:941945.
- 8BaimDS,LeonMB,GreenbergJ,etal.Randomizedtrialofadistalembolicprotectiondeviceduringpercutaneousinterventionofasaphenousveinaortic coronarybypassgrafts.Circulation,2002,105:12851290.
- 9ExaireJE,BrenerSJ,EllisSG,etal.GuardWireemboliprotectiondeviceisassociatedwithimprovedmyocardialperfusiongradeinsaphenousveingraftintervention.AmHeartJ,2004,148:10031006.
- 10GrubeE,GerckensU,YeungAC,etal.Preventionofdistalembolizationduringcoronaryangioplastyinsaphenousveingraftsandnativevesselsusingporousfilterprotection.Circulation,2001,104:24362441.
- 11StoneGW,RogersC,HermillerJ,etal.Randomizedcomparisonofdistalprotectionwithafilter basedcatheterandaballoonocclusionandaspirationsystemduringpercutaneousinterventionofdiseasedsaphenousveinaorto coronarybypassgrafts.Circulation,2003,108:548553.
- 12CoxD,MasudA,MyersF,etal.StentinginSaphenousVeinGraftswithDistalProtectionUsingtheSecondGenerationFilterWireEZ:TheBLAZERegistry.AmJCardiol,2003,92:33L.
- 13TomohiroN,NorifumiK,YuichiS,etal.Effectsofadistalprotectiondeviceduringprimarystentinginpatientswithacuteanteriormyocardialinfarction.CircJ,2004,68:763768.
- 14MakKH,PhayC,WongA,etal.ComparisonbetweenglycoproteinIIb/IIIablockadeanddistalprotectiondevicefortherestorationofmyocardialperfusionduringpercutaneouscoronaryinterventionforacutemyocardialinfarction.JInvasiveCardiol,2004,16:694698.
- 15WuCJ,YangCH,FangCY,etal.Six monthangiographicresultsofprimaryangioplastywithadjunctivePercuSurgeGuardWiredevicesupport:evaluationoftherestenoticrateofthetargetlesionandthefateofthedistalballoonocclusionsite.CatheterCardiovascInterv,2005,64:3542.
- 16YipHK,ChenMC,ChangHW,etal.TransradialapplicationofPercuSurgeGuardWiredeviceduringprimarypercutaneousinterventionofinfarct relatedarterywithhigh burdenthrombusformation.CatheterCardiovascInterv,2004,61:503511.
- 17BlakeJW,WebsterMW,ButlerR,etal.Stentdeploymentwithdistalvascularprotectionfortheculpritveingraftstenosisinapatientwithanacuteinfarctandcardiogenicshock.CatheterCardiovascInterv,2002,57:234238.
- 18王乐丰,杨新春,佟子川,等.远端保护装置AngioguardTM在急性心肌梗死急诊经皮冠状动脉介入治疗中的应用.中国介入心脏病学杂志,2003,11:120122.
- 19LimbrunoU,MicheliA,DeCarloM,etal.Mechanicalpreventionofdistalembolizationduringprimaryangioplasty:safety,feasibility,andimpactonmyocardialreperfusion.Circulation,2003,108:171176.
- 20ChenWH,LeePY,NgW,etal.Safetyandfeasibilityoftheuseofadistalfilterprotectiondeviceinpercutaneousrevascularizationofsmallcoronaryarteries.CatheterCardiovascInterv,2004,61:360363.
- 21StoneGW,WebbJ,CoxDA,etal.DistalmicrocirculatoryprotectionduringpercutaneouscoronaryinterventioninacuteST segmentelevationmyocardialinfarction:arandomizedcontrolledtrial.JAMA,2005,293:10631072.
- 22GickM,JanderN,BestehornHP,etal.Randomizedevaluationoftheeffectsoffilter basedprotectiononmyocardialperfusionandinfarctsizeafterprimarypercutaneouscatheterinterventioninmyocardialinfarctionwithandwithoutST segmentelevation.Circulation,2005,112:14621469.
- 23YamaguchiK,HiasaY,TakahashiT.FormationofacoronaryarteryaneurysmafterinflationofaPercuSurgeGuardWiredistalprotectionballoon.CatheterCardiovascInterv,2005,64:8284.
- 24AngeliniA,RubartelliP,MistrorigoF,etal.Distalprotectionwithafilterdeviceduringcoronarystentinginpatientswithstableandunstableangina.Circulation,2004,110:515521.