利用瞬时无波形比值评估冠状动脉病变及指导血运重建的研究进展
高斯德,刘青波,陈晖
摘要(Abstract):
<正>11冠状动脉功能学评价概述冠状动脉造影至今仍是评估冠状动脉解剖学狭窄程度的核心方法。对于临界病变,主观判断的造影结果并不能真实反映狭窄程度与心肌缺血的关系,随着新技术的进步,冠状动脉检查已从单纯的解剖学评价发展至如今的功能学评价,即利用血流或压力指标来综合判定狭窄病变能否继发引起下游供血范围内的心肌缺血[1]。1993年Pijls等[2]提出冠状动脉血流储备分数(fractional flow reverse,FFR),并定义为病变血管提供给心肌的最大血
关键词(KeyWords): 冠状动脉功能学评价;血流储备分数;瞬时无波形比值;血运重建
基金项目(Foundation):
作者(Author): 高斯德,刘青波,陈晖
参考文献(References):
- [1]陈俊,张璋,于铁链.冠心病诊断:从解剖成像到功能评价.中国介入心脏病学杂志,2017,25(3):166-168.
- [2]Pijls NH,van Son JA,Kirkeeide RL,et al.Experimental basis of determining maximum coronary,myocardial,and collateral blood flow by pressure measurements for assessing f unctional stenosis severity before and after percutaneous transluminal coronary angioplasty.Circulation,1993,87(4):1354-1367.
- [3]杨峻青,李泽杭,涂圣贤.血流储备分数的原理、验证与发展.中国介入心脏病学杂志,2017,25(8):464-468.
- [4]Pijls NH,van Schaardenburgh P,Manoharan G,et al.Percutaneous coronary intervention of functionally nonsignifi cant stenosis:5-year follow-up of the DEFER Study.J Am Coll Cardiol,2007,49(21):2105-2111.
- [5]Tonino PA,De Bruyne B,Pijls NH,et al.Fractional fl ow reserve versus angiography for guiding percutaneous coronary intervention.N Engl J Med,2009,360(3):213-224.
- [6]Pijls NH,Fearon WF,Tonino PA,et al.Fractional fl ow reserve versus angiography for guiding percutaneous coronary intervention in patients with multivessel coronary artery disease:2-year followup of the FAME(Fractional Flow Reserve Versus Angiography for Multivessel Evaluation)study.J Am Coll Cardiol,2010,56(3):177-184.
- [7]Windecker S,Kolh P,Alfonso F,et al.2014 ESC/EACTS Guidelines on myocardial revascularization:the task force on myocardial revascularization of the European Society of Cardiology(ESC)and the European Association for Cardio-Thoracic Surgery(EACTS)developed with the special contribution of the European Association of Percutaneous Cardiovascular Interventions(EAPCI).Eur Heart J,2014,35(37):2541-2619.
- [8]冠状动脉血流储备分数临床应用专家共识专家组.冠状动脉血流储备分数临床应用专家共识.中华心血管病杂志,2016,44(4):292-297.
- [9]陈盈文,胡允兆,吴焱贤,等.血流储备分数在冠状动脉复杂病变经皮冠状动脉介入治疗中的应用.中国介入心脏病学杂志,2015,23(6):320-325.
- [10]宋荟芬,李红,李响,等.血流储备分数与冠状动脉造影指导的治疗对急性冠状动脉综合征患者冠状动脉中度狭窄病变预后的影响.中国介入心脏病学杂志,2016,24(4):186-190.
- [11]G?tberg M,Cook CM,Sen S,et al.The Evolving Future of Instantaneous Wave-Free Ratio and Fractional Flow Reserve.J Am Coll Cardiol,2017,70(11):1379-1402.
- [12]Gould KL,Lipscomb K,Hamilton GW.Physiologic basis for assessing critical coronary stenosis.Instantaneous fl ow response and regional distribution during coronary hyperemia as measures of coronary fl ow reserve.Am J Cardiol,1974,33(1):87-94.
- [13]Nijjer SS,de Waard GA,Sen S,et al.Coronary pressure and flow relationships in humans:phasic analysis of normal and pathological vessels and the implications for stenosis assessment:a report from the Iberian-Dutch-English(IDEAL)collaborators.Eur Heart J,2016,37(26):2069-2080.
- [14]Sen S,Escaned J,Malik IS,et al.Development and validation of a new adenosine-independent index of stenosis severity from coronary wave-intensity analysis:results of the ADVISE(ADenosine Vasodilator Independent Stenosis Evaluation)study.J Am Coll Cardiol,2012,59(15):1392-1402.
- [15]Berry C,van't Veer M,Witt N,et al.VERIFY(VERification of Instantaneous Wave-Free Ratio and Fractional Flow Reserve for the Assessment of Coronary Artery Stenosis Severity in Everyda Y Practice):a multicenter study in consecutive patients.J Am Coll Cardiol,2013,61(13):1421-1427.
- [16]Hennigan B,Oldroyd KG,Berry C,et al.Discordance Between Resting and Hyperemic Indices of Coronary Stenosis Severity:The VERIFY 2 Study(A Comparative Study of Resting Coronary Pressure Gradient,Instantaneous Wave-Free Ratio and Fractional Flow Reserve in an Unselected Population Referred for Invasive Angiography).Circ Cardiovasc Interv,2016,9(11).[Epub ahead of print]
- [17]Johnson NP,Kirkeeide RL,Asrress KN,et al.Does the instantaneous wave-free ratio approximate the fractional fl ow reserve?J Am Coll Cardiol,2013,61(13):1428-1435.
- [18]Petraco R,Al-Lamee R,Gotberg M,et al.Real-time use of instantaneous wave-free ratio:results of the ADVISE in-practice:an international,multicenter evaluation of instantaneous wave-free ratio in clinical practice.Am Heart J,2014,168(5):739-748.
- [19]Escaned J,Echavarría-Pinto M,Garcia-Garcia HM,et al.Prospective Assessment of the Diagnostic Accuracy of Instantaneous WaveFree Ratio to Assess Coronary Stenosis Relevance:Results of ADVISE II International,Multicenter Study(ADenosine Vasodilator Independent Stenosis Evaluation II).JACC Cardiovasc Interv,2015,8(6):824-833.
- [20]Jeremias A,Maehara A,Généreux P,et al.Multicenter core laboratory comparison of the instantaneous wave-free ratio and resting Pd/Pa with fractional flow reserve:the RESOLVE study.J Am Coll Cardiol,2014,63(13):1253-1261.
- [21]Park JJ,Petraco R,Nam CW,et al.Clinical validation of the resting pressure parameters in the assessment of f unctionally signifi cant coronary stenosis;results of an independent,blinded comparison with f ractional flow reserve.Int J Cardiol,2013,168(4):4070-4075.
- [22]H?rle T,Bojara W,Meyer S,et al.Comparison of instantaneous wave-free ratio(i FR)and fractional fl ow reserve(FFR)--fi rst real world experience.Int J Cardiol,2015,199:1-7.
- [23]Shiode N,Okimoto T,Tamekiyo H,et al.A Comparison between the Instantaneous Wave-free Ratio and Resting Distal Coronary Artery Pressure/Aortic Pressure and the Fractional Flow Reserve:The Diagnostic Accuracy Can Be Improved by the Use of both Indices.Intern Med,2017,56(7):749-753.
- [24]Indolfi C,Mongiardo A,Spaccarotella C,et al.The instantaneous wave-free ratio(i FR)for evaluation of non-culprit lesions in patients with acute coronary syndrome and multivessel disease.Int J Cardiol,2015,178:46-54.
- [25]Ding WY,Nair S,Appleby C.Diagnostic accuracy of instantaneous wave free-ratio in clinical practice.J Interv Cardiol,2017,30(6):564-569.
- [26]Petraco R,Park JJ,Sen S,et al.Hybrid i FR-FFR decision-making strategy:implications f or enhancing universal adoption of physiology-guided coronary revascularisation.Euro Intervention,2013,8(10):1157-1165.
- [27]Rivero F,Cuesta J,Bastante T,et al.Diagnostic accuracy of a hybrid approach of instantaneous wave-free ratio and fractional fl ow reserve using high-dose intracoronary adenosine to characterize intermediate coronary lesions:Results of the PALS(Practical Assessment of Lesion Severity)prospective study.Catheter Cardiovasc Interv,2017,90(7):1070-1076.
- [28]Sen S,Asrress KN,Nijjer S,et al.Diagnostic classifi cation of the instantaneous wave-free ratio is equivalent to fractional fl ow reserve and is not improved with adenosine administration.Results of CLARIFY(Classifi cation Accuracy of Pressure-Only Ratios Against Indices Using Flow Study).J Am Coll Cardiol,2013,61(13):1409-1420.
- [29]PetracoR, vande Hoef TP, Nijjer S, et al.Baseline instantaneous wave-free ratio as a pressure-only estimation of underlying coronary fl ow reserve:results of the JUSTIFY-CFR Study(Joined Coronary Pressure and Flow Analysis to Determine Diagnostic Characteristics ofBasalandHyperemicIndicesofFunctionalLesion SeverityCoronary Flow Reserve).Circ Cardiovasc Interv,2014,7(4):492-502.
- [30]vandeHoef TP, Meuwissen M, Escaned J,et al.Head-to-head comparison of basal stenosis resistance index, instantaneous wavefreeratio, and fractional flowreserve:diagnostic accuracy for stenosis-specifi c myocardial ischaemia.EuroIntervention,2015,11(8):914-925.
- [31]HwangD, JeonKH, LeeJM, et al.Diagnostic Performance of RestingandHyperemicInvasivePhysiologicalIndicestoDefine MyocardialIschemia:Validation With 13N-AmmoniaPositron Emission Tomography.JACC CardiovascInterv,2017,10(8):751-760.
- [32]Petraco R, Sen S, Nijjer S, et al.Baseline coronary pressures, instant wave-freeratio(iFR)andPd/Pa:makingthemost of available information.EuroIntervention,2013,9(1):123-170.
- [33]CookCM, Ahmad Y, Shun-Shin MJ, et al.Quantification of the Effect ofPressure WireDrift ontheDiagnosticPerformance of FractionalFlowReserve,InstantaneousWave-FreeRatio,and Whole-Cycle Pd/Pa.Circ Cardiovasc Interv,2016,9(4):e002988.
- [34]Kobayashi Y, Johnson NP, Zimmermann FM, et al.Agreement of the Resting Distal to Aortic Coronary Pressure With the Instantaneous Wave-Free Ratio.J Am Coll Cardiol,2017,70(17):2105-2113.
- [35]Lee JM, Park J, Hwang D, et al.Similarity and Difference of Resting Distalto Aortic CoronaryPressure and Instantaneous Wave-Free Ratio.J Am Coll Cardiol,2017,70(17):2114-2123.
- [36]de Waard GA, Di Mario C, Lerman A,et al.Instantaneous wave-freeratiotoguidecoronaryrevascularisation:physiological framework, validation and differences from fractional fl ow reserve.Euro Intervention,2017,13(4):450-458.
- [37]Thim T, G?tberg M, Fr?bert O, et al.Nonculprit Stenosis Evaluation Using Instantaneous Wave-Free Ratio in Patients With ST-Segment Elevation Myocardial Infarction.JACC Cardiovasc Interv,2017,10(24):2528-2535.
- [38]Musto C, De Felice F, Rigattieri S, et al.Instantaneous wave-free ratio and fractional flowreserve for the assessment ofnonculprit lesionsduringtheindexprocedureinpatientswith ST-segment elevationmyocardial infarction:The WAVE study.Am Heart J,2017,193:63-69.
- [39]NijjerSS, SenS, PetracoR, et al. Improvementincoronary haemodynamicsaf terpercutaneouscoronaryintervention:assessment using instantaneous wave-free ratio.Heart,2013,99(23):1740-1748.
- [40]Nijjer SS, Sen S, Petraco R, et al.The Instantaneous wave-Free Ratio(i FR)pullback:a novel innovation using baseline physiology to optimise coronary angioplasty in tandem lesions.Cardiovasc Revasc Med,2015,16(3):167-171.
- [41]Kobayashi Y, Johnson NP, Berry C, et al.The Infl uence of Lesion Location on the Diagnostic Accuracy of Adenosine-Free Coronary Pressure Wire Measurements.JACC Cardiovasc Interv,2016,9(23):2390-2399.
- [42]Davies JE, Sen S, Dehbi HM, et al.Use of the Instantaneous Wavefree Ratio or Fractional Flow Reserve in PCI.N Engl J Med,2017,376(19):1824-1834.
- [43]G?tberg M, Christiansen EH, Gudmundsdottir IJ, et al.Instantaneous Wave-freeRatioversusFractionalFlowReserveto GuidePCI.N Engl J Med,2017,376(19):1813-1823.