磁共振兼容性心脏电子植入装置的临床应用
万征,李洪仕
摘要(Abstract):
<正>核磁共振成像(magnetic resonance imaging,MRI)具有高分辨率、无射线辐射和不需注射碘对比剂等优点,在软组织、骨关节和心脏成像方面具有其他影像技术不可比拟的优势,但不能用于植入心脏电子植入装置(cardiac implantable electrical device,CIED)的患者[1]。据统计,美国大约有2×106例患者装有CIED,其中50%~75%具有MRI检查适应
关键词(KeyWords): 核磁共振成像;心脏植入电子装置;磁场
基金项目(Foundation):
作者(Author): 万征,李洪仕
参考文献(References):
- [1]Scholtz L,Sarkin A,Lockhat Z.Current clinical applications of cardiovascular magnetic resonance imaging.Cardiovasc J Afr,2014,25:185-190.
- [2]Chow GV,Nazarian S.MRI for patients with cardiac implantable electrical devices.Cardiol Clin,2014,32:299-304.
- [3]Gimbel JR,Johnson D,Levine PA,et al.Safe performance of magnetic resonance imaging on five patients with permanent cardiac pacemakers.Pacing Clin Electrophysiol,1996,19:913-919.
- [4]Sommer T,Vahlhaus C,Lauck G,et al.MR imaging and cardiac pacemakers:in-vitro evaluation and in-vivo studies in 51patients at 0.5 T.Radiology,2000,215:869-879.
- [5]Martin ET,Coman JA,Shellock FG,et al.Magnetic resonance imaging and cardiac pacemaker safety at 1.5-Tesla.J Am Coll Cardiol,2004,43:1315-1324.
- [6]Levine GN,Gomes AS,Arai AE,et al.Safety of magnetic resonance imaging in patients with cardiovascular devices:an American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization,Council on Clinical Cardiology,and the Council on Cardiovascular Radiology and Intervention:endorsed by the American College of Cardiology Foundation,the North American Society for Cardiac Imaging,and the Society for Cardiovascular Magnetic Resonance.Circulation,2007,116:2878-2891.
- [7]Gotte MJ,Rüssel IK,de Roest GJ,et al.Magnetic resonance imaging,pacemakers and implantable cardioverter-defibrillators:current situation and clinical perspective.Neth Heart J,2010,18:31-37.
- [8]Nazarian S,Beinart R,Halperin HR.Magnetic resonance imaging and implantable devices.Circ Arrhythm Electrophysiol,2013,6:419-428.
- [9]Bovenschulte H,Schlüter-Brust K,Liebig T,et al.MRI in patients with pacemakers:overview and procedural management.Dtsch Arztebl Int,2012,109:270-275.
- [10]Luechinger R,Duru F,Scheidegger MB,et al.Force and torque effects of a 1.5-Tesla MRI scanner on cardiac pacemakers and ICDs.Pacing Clin Electrophysiol,2001,24:199-205.
- [11]Luechinger R,Duru F,Zeijlemaker VA,et al.Pacemaker reed switch behavior in 0.5,1.5,and 3.0 Tesla magnetic resonance imaging units:are reed switches always closed in strong magnetic fields?Pacing Clin Electrophysiol,2002,25:1419-1423.
- [12]Ahmed FZ,Morris GM,Allen S,et al.Not all pacemakers are created equal:MRI conditional pacemaker and lead technology.J Cardiovasc Electrophysiol,2013,24:1059-1065.
- [13]Roguin A,Zviman MM,Meininger GR,et al.Modern pacemaker and implantable cardioverter/defibrillator systems can be magnetic resonance imaging safe:in vitro and in vivo assessment of safety and function at 1.5 T.Circulation,2004,110:475-482.
- [14]Nordbeck P,Ertl G,Ritter O.Magnetic resonance imaging safety in pacemaker and implantable cardioverter defibrillator patients:how far have we come?Eur Heart J,2015,36:1505-1511.
- [15]Jung W,Zvereva V,Hajredini B,et al.Safe magnetic resonance image scanning of the pacemaker patient:current technologies and future directions.Europace,2012,14:631-637.
- [16]van der Graaf AW,Bhagirath P,Gtte MJ.MRI and cardiac implantable electronic devices;current status and required safety conditions.Neth Heart J,2014,22:269-276.
- [17]Hundley WG,Bluemke DA,Finn JP,et al.ACCF/ACR/AHA/NASCI/SCMR 2010 expert consensus document on cardiovascular magnetic resonance:a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents.J Am Coll Cardiol,2010,55:2614-2662.
- [18]Cronin EM,Wilkoff BL.Magnetic resonance imaging conditional pacemakers:rationale,development and future directions.Indian Pacing Electrophysiol J,2012,12:204-212.
- [19]Ferreira AM,Costa F,Tralho A,et al.MRI-conditional pacemakers:current perspectives.Med Devices(Auckl),2014,7:115-124.
- [20]Jung W,Jckle S,Zvereva V.MRI and implantable cardiac electronic devices.Curr Opin Cardiol,2015,30:65-73.
- [21]Cohen JD,Costa HS,Russo RJ.Determining the risks of magnetic resonance imaging at 1.5 tesla for patients with pacemakers and implantable cardioverter defibrillators.Am J Cardiol,2012,110:1631-1636.
- [22]Wilkoff BL,Bello D,Taborsky M,et al.Magnetic resonance imaging in patients with a pacemaker system designed for the magnetic resonance environment.Heart Rhythm,2011,8:65-73.
- [23]Wollmann CG,Thudt K,Kaiser B,et al.Safe performance of magnetic resonance of the heart in patients with magnetic resonance conditional pacemaker systems:the safety issue of the ESTIMATE study.J Cardiovasc Magn Reson,2014,16:30.
- [24]Wollmann CG,Steiner E,Vock P,et al.Monocenter feasibility study of the MRI compatibility of the Evia pacemaker in combination with Safio S pacemaker lead.J Cardiovasc Magn Reson,2012,14:67.
- [25]Maglia G,Curnis A,Brieda M,et al.Assessing access to MRI of patients with magnetic resonance-conditional pacemaker and implantable cardioverter defibrillator systems:the Really Pro MRI study design.J Cardiovasc Med(Hagerstown),2014.[Epub ahead of print]
- [26]Gimbel JR.Magnetic resonance imaging of implantable cardiac rhythm devices at 3.0 tesla.Pacing Clin Electrophysiol,2008,31:795-801.
- [27]Gimbel JR.Unexpected asystole during 3T magnetic resonance imaging of a pacemaker-dependent patient with a'modern'pacemaker.Europace,2009,11:1241-1242.
- [28]Gimbel JR.Unexpected pacing inhibition upon exposure to the 3T static magnetic field prior to imaging acquisition:what is the mechanism?Heart Rhythm,2011,8:944-945.
- [29]Kodali S,Baher A,Shah D.Safety of MRIs in patients with pacemakers and defibrillators.Methodist Debakey Cardiovasc J,2013,9:137-141.