完全可降解聚乳酸西罗莫司洗脱支架在小型猪冠状动脉模型中的实验研究Preliminary evaluation of fully bioabsorbable PLLA sirolimus eluting stents in a porcine model
沈雳,王齐兵,吴轶喆,谢建,张峰,葛雷,葛均波
摘要(Abstract):
目的评价新型全降解聚乳酸西罗莫司洗脱支架(XinsorbTM)在小型猪冠状动脉抑制新生内膜增殖的有效性和安全性。方法裸金属支架(Bare metal stent,BMS)16枚和Xinsorb支架16枚分别随机置入16头小型猪的前降支(16枚)和右冠状动脉(16枚)。置入30d和90d,复查冠状动脉造影后处死部分动物取出支架段血管,将支架分成等长的两部分,一半用树脂包埋后制作硬组织切片,苏木素和伊红染色(haematoxylin and eosin,HE)分析组织形态,评价新生内膜增殖及管腔狭窄率;另一半用戊二醛固定后用扫描电镜观察支架段血管内皮化情况。结果 Xinsorb支架置入后未出现支架内血栓,并有效防止血管弹性回缩造成的血管狭窄。病理分析提示:置入30d,Xinsorb支架比BMS能显著减少新生内膜面积(0.9±0.2)mm2比(2.2±0.2)mm2(P<0.05)和管腔狭窄面积(19.3±3.4)%比(38.2±5.3)%(P<0.05),置入30d时BMS内皮化完全,但Xinsorb支架表面有部分未完全内皮化,Xinsorb支架内皮化完全所需的时间在30~90d。结论 Xinsorb支架在置入小型猪冠状动脉90d内,可以有效地支撑血管壁防止弹性回缩并抑制新生内膜增殖,在置入早期轻度延迟内皮的修复。
关键词(KeyWords): 药物洗脱支架;冠状动脉再狭窄;内皮,血管;西罗莫司
基金项目(Foundation): 国家重点基础研究发展计划(2011CB503905);; 上海市科学技术委员会资助(11441900300);; 上海市青年科技启明星(跟踪)计划(11QH1400500)
作者(Author): 沈雳,王齐兵,吴轶喆,谢建,张峰,葛雷,葛均波
参考文献(References):
- [1]Sousa JE,Costa MA,Sousa AGMR.Two-year angiographic and intravascular ultrasound follow-up after implantation of sirolimus-eluting stents in human coronary arteries.Circulation,2003,107:381-383.
- [2]Stone GW,Ellis SG,Cox DA.A polymer-based,paclitaxel-eluting stent inpatients with coronary arteries diseases.New Eng J Med,2004,350:221-231.
- [3]Joner M,Finn AV,Farb A,et al.Pathology of drug-eluting stents in humans:delayed healing and late thrombotic risk.J Am Coll Cardiol,2006,48:193-202.
- [4]Luscher TF,Steffel J,Eberli FR,et al.Drug-eluting stent and coronary thrombosis:biologicalmechanisms and clinical implications.Circulation,2007,115:1051-1058.
- [5]Kotani J,Awata M,Nanto S,et al.Incomplete neointimal coverage of sirolimus-eluting stents:angioscopic findings.J Am Coll Cardiol,2006,47:2108-2111.
- [6]Wilson GJ,Nakazawa G,Schwartz RS,et al.Comparison of inflammatory response after implantation of sirolimus-and paclitaxel-eluting stents in porcine coronary arteries.Circulation,2009,120:141-149.
- [7]Kimura T,Yokoi H,Nakagawa Y,et al.Three-year follow-up after implantation of metallic coronary artery stents.N Engl J Med,1996,334:561-566.
- [8]Ge J,Qian J,Wang X,et al.Effectiveness and Safety of the Sirolimus-Eluting Stents Coated With Bioabsorbable Polymer Coating in Human Coronary Arteries.Catheter Cardiovasc Interv,2007,69:198-202.
- [9]Windecker S,Serruys PW,Wandel S,et al.Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation(LEADERS):a randomised non-inferiority trial.Lancet,2008,372:1163-1173.
- [10]Serruys PW,Kutryk KJ,Ong AT.Coronary-artery stents.N Engl J Med,2006,354:483-495.
- [11]Wykrzykowska JJ,Onuma Y,Serruys PW.Vascular restoration therapy:the fourth revoluation in interventional cardiology and the ultimate"Rosy"prophecy.Eurointervention,2009,5suppl:F7-F8.
- [12]Onuma Y,Serruys PW,Ormiston JA,et al.Three-year results of clinical follow-up after a bioresorbable everolimus-eluting scaffold in patients with de novo coronary artery disease:the ABSORB trial.EuroIntervention,2010,6:447-453.
- [13]Lincoff AM,Furst JG,Ellis SG,et al.Sustained local delivery of dexamethasone by a novel intravascular eluting s ten t to prevent restenosis in the porcine coronary injury model.J Am Coll Cardiol,1997,29:808-816.
- [14]Virmani R,Guaglium IG,Farb A,et al.Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus eluting stent:Should we be cautious?Circulation,2004,109:701-705.