支架纵向变形:一种“新”的冠状动脉支架并发症
张颖,谷国强,崔炜
摘要(Abstract):
<正>冠状动脉内支架制作技术在过去的30年有了长足的进步。在裸金属支架(BMS)时代,大多数的支架都是由不锈钢制作而成,金属丝的几何形状及厚度有一定的差异[1]。制造商通过对支架物理特性的改良,希望能够制作出医师使用更方便且临床效果良好的支架。随着支架制作技术及手术操作技术的不断进步,经皮冠状动脉介入治疗(PCI)的效果也越来越好。
关键词(KeyWords): 药物洗脱支架;支架纵向变形;冠状动脉狭窄
基金项目(Foundation):
作者(Author): 张颖,谷国强,崔炜
参考文献(References):
- [1]Colombo A,Stankovic G,Moses JW.Selection of coronary stents.J Am Coll Cardiol,2002,40:1021-1033.
- [2]Serruys PW,Silber S,Garg S,et al.Comparison of zotarolimuseluting and everolimus-eluting coronary stents.N Engl J Med,2010,363:136-146.
- [3]Williams PD,Mamas MA,Morgan KP,et al.Longitudinal stent deformation:a retrospective analysis of frequency and mechanisms.EuroIntervention,2012,8:267-274.
- [4]Hanratty CG,Walsh SJ.Longitudinal compression:a"new"complication with modern coronary stent platforms--time to think beyond deliverability?EuroIntervention,2011,7:872-877.
- [5]Mamas MA,Williams PD.Longitudinal stent deformation:insights on mechanisms,treatments and outcomes from the Food and Drug Administration Manufacturer and User Facility Device Experience database.EuroIntervention,2012,8:196-204.
- [6]Aminian A,Lalmand J.Comments on"Longitudinal stent deformation:insights on mechanisms,treatments and outcomes from the FDA Manufacturer and User Facility Device Experience database"by Mamas et al.EuroIntervention,2012,8:990-991.
- [7]Finet G,Rioufol G.Coronary stent longitudinal deformation by compression:is this a new global stent failure,a specific failure of a particular stent design or simply an angiographic detection of an exceptional PCI complication?EuroIntervention,2012,8:177-181
- [8]Hildick-Smith D,Lassen JF,Albiero R,et al.Consensus from the 5th European Bifurcation Club meeting.EuroIntervention,2010,6:34-38.
- [9]Leibundgut G,Gick M,Toma A,et al.Longitudinal compression of the platinum-chromium everolimus-eluting stent during coronary implantation:predisposing mechanical properties,incidence,and predictors in a large patient cohort.Catheter Cardiovasc Interv,2013,81:E206-E214.
- [10]Williams PD,Mamas MA.Longitudinal stent deformation:a retrospective analysis of frequency and mechanisms.EuroIntervention,2012,8:267-274.
- [11]Prabhu S,Schikorr T,Mahmoud T,et al.Engineering assessment of the longitudinal compression behaviour of contemporary coronary stents.EuroIntervention,2012,8:275-281.
- [12]Ormiston JA,Webber B,Webster MW.Stent longitudinal integrity bench insights into a clinical problem.JACC Cardiovasc Interv,2011,4:1310-1317.
- [13]Stone GW,Teirstein PS,Meredith IT,et al.A prospective randomised evaluation of a novel everolimus-eluting coronary stent:the PLATINUM trial.J Am Coll Cardiol,2011,57:1700-1708.
- [14]Kereiakes DJ,Cannon LA,Feldman RL,et al.Clinical and angiographic outcomes after treatment of de novo coronary stenoses with a novel platinum chromium thin-strut stent:Primary results of the PERSEUS(Prospective Evaluation in a Randomized Trial of the Safety and Effi cacy of the Use of the TAXUS Element PaclitaxelEluting Coronary Stent System)trial.J Am Coll Cardiol,2010,56:264-271.
- [15]Stone GW,Teirstein PS,Meredith IT,et al.A prospective,randomized evaluation of a novel everolimus-eluting coronary stent:the PLATINUM(a Prospective,Randomized,Multicenter Trial to Assess an Everolimus-Eluting Coronary Stent System[PROMUS Element]for the Treatment of Up to Two de Novo Coronary Artery Lesions)trial.J Am Coll Cardiol,2011,57:1700-1708.
- [16]Shannon J,Latib A,Takagi K,et al.Procedural trauma risks longitudinal shortening of the Promus Elementstent platform.Catheter Cardiovasc Interv,2013,81:810-817.