经导管主动脉瓣置换术中对合缘对齐和冠状动脉对齐的研究进展Research progress of commissural alignment and coronary alignment during transcatheter aortic valve replacement procedure
奚思宇,张海山,高远,梁长彬,孙英贤,郭亮
摘要(Abstract):
对合缘对齐是指主动脉瓣置换术中将人工瓣膜对合缘与原生瓣膜对合缘对齐,而冠状动脉对齐是指将人工瓣膜对合缘与左、右冠状动脉开口的角平分线对齐。提高对合缘对齐技术和冠状动脉对齐技术,对于避免术中急性冠状动脉闭塞,保证术后有可行的冠状动脉路径以及提高瓣膜的耐久性等问题有着深远的影响。本文就经导管主动脉瓣置换术中对合缘对齐技术和冠状动脉对齐技术的研究进展进行综述。
关键词(KeyWords): 经导管主动脉瓣置换术;对合缘对齐;冠状动脉对齐
基金项目(Foundation):
作者(Author): 奚思宇,张海山,高远,梁长彬,孙英贤,郭亮
参考文献(References):
- [1] Nishimura RA, Otto CM, Bonow RO, et al. 2014 AHA/ACC guideline for the management of patients with valvular heart disease:executive summary:a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines[J]. J Am Coll Cardiol,2014,63(22):2438-2488.
- [2] Vahanian A, Beyersdorf F, Praz F, et al. 2021 ESC/EACTS guidelines for the management of valvular heart disease[J]. Eur Heart J, 2022,43(7):561-632.
- [3] Mack MJ, Leon MB, Thourani VH, et al. Transcatheter aorticvalve replacement with a balloon-expandable valve in low-risk patients[J]. N Engl J Med,2019,380(18):1695-1705.
- [4] Popma JJ, Deeb GM, Yakubov SJ, et al. Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients[J]. N Engl J Med,2019,380(18):1706-1715.
- [5] Tang GHL, Zaid S, Fuchs A, et al. Alignment of transcatheter aortic-valve neo-commissures(ALIGN TAVR):impact on final valve orientation and coronary artery overlap[J]. JACC Cardiovasc Interv,2020,13(9):1030-1042.
- [6] Yudi MB, Sharma SK, Tang GHL, et al. Coronary angiography and percutaneous coronary intervention after transcatheter aortic valve replacement[J]. J Am Coll Cardiol,2018,71(12):1360-1378.
- [7] Buzzatti N, Romano V, De Backer O, et al. Coronary access after repeated transcatheter aortic valve implantation:a glimpse into the future[J]. JACC Cardiovasc Imaging,2020,13(2Pt 1):508-515.
- [8] Fuchs A, Kofoed KF, Yoon SH, et al. Commissural alignment of bioprosthetic aortic valve and native aortic valve following surgical and transcatheter aortic valve replacement and its impact on valvular function and coronary fi lling[J]. JACC Cardiovasc Interv,2018,11(17):1733-1743.
- [9] Redondo A,Baladrón Zorita C,TchétchéD,et al. Commissural versus coronary optimized alignment during transcatheter aortic valve replacement[J]. JACC Cardiovasc Interv,2022,15(2):135-146.
- [10] Wang X, De Backer O, Bieliauskas G, et al. Cusp symmetry and coronary ostial eccentricity and its impact on coronary access following TAVR[J]. JACC Cardiovasc Interv,2022,15(2):123-134.
- [11] Arai T, Lefèvre T, Hovasse T, et al. Incidence and predictors of coronary obstruction following transcatheter aortic valve implantation in the real world[J]. Catheter Cardiovasc Interv,2017,90(7):1192-1197.
- [12]刘先宝,高晨阳,王建安.经导管主动脉瓣置换术中急性冠状动脉闭塞的危险因素及其处理[J].上海医药,2017,38(3):21-23.
- [13] Lederman RJ, Babaliaros VC, Rogers T, et al. Preventing coronary obstruction during transcatheter aortic valve replacement:from computed tomography to BASILICA[J].JACC Cardiovasc Interv,2019,12(13):1197-1216.
- [14] Jilaihawi H. When the(Commissural)Stars(Mis)ALIGN[J].JACC Cardiovasc Interv,2020,13(9):1043-1045.
- [15] Bernardi FLM, Dvir D, Rodes-Cabau J, et al. Valve-in-valve challenges:how to avoid coronary obstruction[J]. Front Cardiovasc Med,2019,6:120.
- [16] Faroux L, Guimaraes L, Wintzer-Wehekind J, et al. Coronary artery disease and transcatheter aortic valve replacement:JACC state-of-the-art review[J]. J Am Coll Cardiol,2019,74(3):362-372.
- [17] Abdelghani M, Landt M, Traboulsi H, et al. Coronary access after TAVR with a self-expanding bioprosthesis:insights from computed tomography[J]. JACC Cardiovasc Interv,2020,13(6):709-722.
- [18] Ochiai T, Chakravarty T, Yoon SH, et al. Coronary access after TAVR[J]. JACC Cardiovasc Interv,2020,13(6):693-705.
- [19] Gunning PS, Vaughan TJ, McNamara LM. Simulation of self expanding transcatheter aortic valve in a realistic aortic root:implications of deployment geometry on leafl et deformation[J].Ann Biomed Eng,2014,42(9):1989-2001.
- [20] Yoon SH,Kim WK,Dhoble A,et al. Bicuspid aortic valve morphology and outcomes after transcatheter aortic valve replacement[J]. J Am Coll Cardiol,2020,76(9):1018-1030.
- [21] Choudhury T, Solomonica A, Bagur R. The ACURATE neo transcatheter aortic valve system[J]. Expert Rev Med Devices,2018,15(10):693-699.
- [22] Kitamura M, Wilde J, Gohmann R, et al. Commissural alignment of the ACURATE neo valve in transcatheter aortic valve replacement[J]. JACC Cardiovasc Interv,2021,14(15):1740-1742.
- [23] Bieliauskas G, Wong I, Bajoras V, et al. Patient-specific implantation technique to obtain neo-commissural alignment with self-expanding transcatheter aortic valves[J]. JACC Cardiovasc Interv,2021,14(19):2097-2108.
- [24] De Marco F, Casenghi M, Spagnolo P, et al. A patientspecifi c algorithm to achieve commissural alignment with Acurate Neo:The sextant technique[J]. Catheter Cardiovasc Interv,2021,98(6):E847-E854.
- [25] Tang GHL, Zaid S, Ahmad H, et al. Transcatheter valve neocommissural overlap with coronary orifices after transcatheter aortic valve replacement[J]. Circ Cardiovasc Interv,2018,11(10):e007263.
- [26] Tang GHL, Zaid S, Gupta E, et al. Impact of initial evolut transcatheter aortic valve replacement deployment orientation on final valve orientation and coronary reaccess[J]. Circ Cardiovasc Interv,2019,12(7):e008044.
- [27] Tang GHL, Sengupta A, Alexis SL, et al. Conventional versus modified delivery system technique in commissural alignment from the Evolut low-risk CT substudy[J]. Catheter Cardiovasc Interv,2022,99(3):924-931.
- [28] Kitamura M, Wilde J, Dumpies O, et al. Patient-specific neocommissural alignment of the evolut valve:a pilot study in transcatheter aortic valve-in-valve replacement[J]. JACC Cardiovasc Interv,2021,14(8):934-936.