可调弯鞘管与普通鞘管在右心房心房扑动患者三尖瓣峡部线射频消融中的应用比较Comparison between the effect of the steerable sheath and general sheath on the radiofrequency ablation of cavo-tricuspid isthmus in subjects with right atrial flutter
王新国,张涛,方冬平,梁卓,刘旭,李巧元,李延广,王云龙
摘要(Abstract):
目的 探讨右心房心房扑动(房扑)患者三尖瓣峡部线消融中可调弯鞘管应用对射频消融疗效的影响。方法 本研究纳入2023年1月至2024年3月首都医科大学附属北京安贞医院行射频消融治疗的房扑患者,分为可调弯鞘管组和普通鞘管组。比较两组射频消融术中的消融时间和消融点数及单次三尖瓣峡部线阻滞率、观察期间三尖瓣峡部线电传导再次连接率。定期门诊随访和电话随访,比较两组房扑临床复发情况。结果 共纳入房扑患者183例,可调弯鞘管组54例,普通鞘管组129例。可调弯鞘管组患者行射频消融治疗术中消融点数明显少于普通鞘管组[(14.0±6.6)个比(17.3±9.2)个,P=0.011],消融时间明显减少[(9.6±4.2)min比(12.3±7.5)min,P=0.008],单次消融三尖瓣峡部线双向阻滞率更高(90.7%比72.1%,P=0.006),观察期间三尖瓣峡部线电传导再次连接率更低(1.9%比14.0%,P=0.015),差异均有统计学意义。结论 房扑患者三尖瓣峡部线消融采用可调弯鞘管可提高射频消融效率,提高三尖瓣峡部线单次双向阻滞成功率,降低观察期间三尖瓣峡部线电传导再次连接率。
关键词(KeyWords): 心房扑动;三尖瓣-下腔静脉峡部;射频消融;可调弯鞘管;双向阻滞
基金项目(Foundation):
作者(Author): 王新国,张涛,方冬平,梁卓,刘旭,李巧元,李延广,王云龙
参考文献(References):
- [1]王华,李博,郝京霞,等.术中峡部传导间期百分比对典型心房扑动导管消融终点判定的有效性评估[J].中国介入心脏病学杂志,2023,31(10):911-914. DOI:10.3969/j. issn.1004-8812.2023. 12.004.
- [2]马可忠,周汉云,杨峰,等.En Site NavXTM系统指引下X线零曝光经导管射频消融治疗典型心房扑动[J].中国介入心脏病学杂志,2017,25(1):17-20. DOI:10.3969/j.issn.1004-8812.2017.01.005.
- [3]Schillaci V,Strisciuglio T,Stabile G,et al.Cavotricuspid isthmus ablation by means of very high power, short-duration,temperature-controlled lesions[J].J Interv Card Electrophysiol,2022,65(1):97-102. DOI:10.1007/s10840-022-01197-x.
- [4]Chikata A,Kato T,Usuda K,et al.Ablation index-guided highpower vs. moderate-power cavotricuspid isthmus ablation[J].Heart Vessels,2023,38(1):90-95. DOI:10.1007/s00380-022-02125-9.
- [5]Yoneda ZT,Shoemaker MB,Richardson T,et al.Conduction recovery after cavotricuspid isthmus ablation when performed with or without concomitant atrial fibrillation ablation[J].JACC Clin Electrophysiol,2020,6(8):989-996. DOI:10.1016/j.jacep.2020.04.031.
- [6]Zhang T,Wang Y,Han Z,et al.Cavotricuspid isthmus ablation using ablation index in typical right atrial flutter[J].J Cardiovasc Electrophysiol,2019,30(11):2414-2419. DOI:10.1111/jce.14156.
- [7]Peyrol M,Sbragia P.Typical atrial flutter-when do you say you have got it[J].J Atr Fibrillation,2012,5(3):712. DOI:10.1371/jafib.712.
- [8]Matsuo S,Yamane T,Tokuda M,et al.Prospective randomized comparison of a steerable versus a non-steerable sheath for typical atrial flutter ablation[J].Europace,2010,12(3):402-409.DOI:10.1093/europace/eup434.
- [9]Fuding G,Xiaohua Z,Sen Y,et al.Enhanced procedural efficacy in typical atrial flutter ablation with a visualizable steerable sheath[J].Pacing Clin Electrophysiol,2025,48(3):294-301. DOI:10.1111/pace.15143.
- [10]Viola G,Stabile G,Bandino S,et al.Safety,efficacy,and reproducibility of cavotricuspid isthmus ablation guided by the ablation index:acute results of the FLAI study[J].Europace,2021,23(2):264-270.DOI:10.1093/europace/euaa215.
- [11]Kashiwagi M,Kuroi A,Higashimoto N,et al.Impact of tag index and local electrogram for successful first-pass cavotricuspid isthmus ablation[J].Heart rhythm O2,2023,4(6):350-358. DOI:10.1016/j.hroo.2023.04.002.
- [12]Murayama Y,Kishihara J,Fukaya H,et al.Lesion size index-guided cavotricuspid isthmus linear ablation[J].J Interv Card Electrophysiol,2023,66(2):485-492. DOI:10.1007/s10840-022-01360-4.
- [13]Penela D,Chauca A,Fernández-Armenta J,et al.Outcomes of cavotricuspid isthmus-dependent flutter ablation:randomized study comparing single vs. multiple catheter procedures-the SIMPLE study[J].J Interv Card Electrophysiol,2023,66(9):1979-1988.DOI:10.1007/s10840-023-01511-1.
- [14]Maglia G,Pentimalli F,Verlato R,et al. Ablation of CTI-dependent flutter using different ablation technologies:acute and long-term outcome from the LEONARDO study[J].J Interv Card Electrophysiol,2023,66(7):1749-1757. DOI:10.1007/s10840-023-01519-7.
- [15]Asvestas D,Sousonis V,Kotsovolis G,et al.Cavotricuspid isthmus ablation guided by force-time integral-a randomized study[J].Clin Cardiol,2022,45(5):503-508. DOI:10.1002/clc.23805.
- [16]Gami AS,Edwards WD,Lachman N,et al.Electrophysiological anatomy of typical atrial flutter:the posterior boundary and causes for difficulty with ablation[J].J Cardiovasc Electrophysiol,2010,21(2):144-149. DOI:10.1111/j.1540-8167.2009.01607.x.
- [17]Shimizu Y,Yoshitani K,Murotani K,et al.The deeper the pouch is,the longer the radiofrequency duration and higher the radiofrequency energy needed-Cavotricuspid isthmus ablation using intracardiac echocardiography[J].J Arrhythm, 2018,34(4):410-417.DOI:10.1002/joa3.12075.
- [18]李康,范芳芳,王禹川,等.三尖瓣峡部的心腔内超声解剖学特征[J].中国心脏起搏与心电生理杂志,2022,36(2):123-128. DOI:10.13333/j.cnki.cjcpe.2022.02.007.
- [19]Kewcharoen J,Shah K,Bhardwaj R,et al.Post-FDA approval"realworld"safety profile of different steerable sheaths during catheter ablation:a Food and Drug Administration MAUDE database study[J].Heart Rhythm,2022,19(5):856-857. DOI:10.1016/j.hrthm.2021.12.034.