家庭监测系统在心脏电子植入装置患者随访中的应用
解玉泉,李毅刚
摘要(Abstract):
<正>随着心血管疾病患病率的增加,中国近年来植入永久心脏起搏器(pacemaker,PM)、植入型心律转复除颤器(implantable cardioverter defibrillator,ICD)等心脏电子装置患者的数量逐年增加,临床上为观察其效果及预后评估,随访工作日益繁重。既往由患者定期到医院随访的模式已不能满足现代医学的需求,随着生物信号远程监测技术、信号工
关键词(KeyWords): 家庭监测系统;心脏;电子植入装置
基金项目(Foundation): 上海市科委资助项目(14441902502、13140903801、12411951900)
作者(Author): 解玉泉,李毅刚
参考文献(References):
- [1]Wilkoff BL,Auricchio A,Brugada J,et al.HRS/EHRA expert consensus on the monitoring of cardiovascular implantable electronic devices(CIEDs):description of techniques,indications,personnel,frequency and ethical considerations.Heart Rhythm,2008,5:907-925.
- [2]张澍,陈柯萍,黄德嘉,等.心血管植入型电子器械术后随访的专家共识.中华心律失常学杂志,2012,16:325-329.
- [3]戴研,杨杰孚,周玉杰,等.家庭监测系统在双腔起搏器植入患者中的多中心注册研究.中国循环杂志,2013,28:29-32.
- [4]张颖,任晓庆,王方正,等.心脏起搏器植入后的规范化随访与程控.中国分子心脏病学杂志,2012,12:146-149.
- [5]Ricci RP,Morichelli L,D'Onofrio A,et al.Manpower and outpatient clinic workload for remote monitoring of patients with cardiac implantable electronic devices:data from the Home Guide Registry.J Cardiovasc Electrophysiol,2014,25:1216-1223.
- [6]Varma N,Michalski J,Stambler B,et al.Superiority of automatic remote monitoring compared with in-person evaluation for scheduled ICD follow-up in the TRUST trial-testing execution of the recommendations.Eur Heart J,2014,35:1345-1352.
- [7]Crossley GH,Boyle A,Vitense H,et al.The CONNECT(Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision)trial:the value of wireless remote monitoring with automatic clinician alerts.J Am Coll Cardiol,2011,57:1181-1189.
- [8]Guédon-Moreau L,Kouakam C,Klug D,et al.Decreased delivery of inappropriate shocks achieved by remote monitoring of ICD:a substudy of the ECOST trial.J Cardiovasc Electrophysiol,2014,25:763-770.
- [9]Narin A,Isler Y,Ozer M.Investigating the performance improvement of HRV Indices in CHF using feature selection methods based on backward elimination and statistical significance.Comput Biol Med,2014,45:72-79.
- [10]Saxon LA,Boehmer JP,Neuman S,et al.Remote Active Monitoring in Patients with Heart Failure(RAPID-RF):design and rationale.J Card Fail,2007,13:241-246.
- [11]Bourge RC,Abraham WT,Adamson PB,et al.Randomized controlled trial of an implantable continuous hemodynamic monitor in patients with advanced heart failure:the COMPASSHF study.J Am Coll Cardiol,2008,51:1073-1079.
- [12]Landolina M,Perego GB,Lunati M,et al.Remote monitoring reduces healthcare use and improves quality of care in heart failure patients with implantable defibrillators:the evolution of management strategies of heart failure patients with implantable defibrillators(EVOLVO)study.Circulation,2012,125:2985-2992.
- [13]Ip J,Waldo AL,Lip GY,et al.Multicenter randomized study of anticoagulation guided by remote rhythm monitoring in patients with implantable cardioverter-defibrillator and CRT-D devices:Rationale,design,and clinical characteristics of the initially enrolled cohort The IMPACT study.Am Heart J,2009,158:364-370.
- [14]Guédon-Moreau L,Lacroix D,Sadoul N,et al.Costs of remote monitoring vs.ambulatory follow-ups of implanted cardioverter defibrillators in the randomized ECOST study.Europace,2014,16:1181-1188.
- [15]Polisena J,Tran K,Cimon K,et al.Home telemonitoring for congestive heart failure:a systematic review and meta-analysis.J Telemed Telecare,2010,16:68-76.
- [16]Koehler F,Winkler S,Schieber M,et al.Telemedical Interventional Monitoring in Heart Failure(TIM-HF),a randomized,controlled intervention trial investigating the impact of telemedicine on mortality in ambulatory patients with heart failure:study design.Eur J Heart Fail,2010,12:1354-1362.
- [17]Desimone CV,Friedman PA,Noheria A,et al.Stroke or transient ischemic attack in patients with transvenous pacemaker or defibrillator and echocardiographically detected patent foramen ovale.Circulation,2013,128:1433-1441.
- [18]Healey JS,Israel CW,Connolly SJ,et al.Relevance of electrical remodeling in human atrial fibrillation:results of the Asymptomatic Atrial Fibrillation and Stroke Evaluation in Pacemaker Patients and the Atrial Fibrillation Reduction Atrial Pacing Trial mechanisms of atrial fibrillation study.Circ Arrhythm Electrophysiol,2012,5:626-631.